Problem 9914: M1C14A3 chamber lost one gap

System
MUON
Severity
Minor
Start date
2017-06-14 08:38
End date
2017-06-19 13:15
Runs affected
Reported by
Sofia Kotriakhova on 2017-06-14 15:02

Comments

#1 by Sofia Kotriakhova on 2017-06-14 15:02

Chamber lost one gap due to broken HV CAEN channel.
Some inefficiency is visible on normalized map for M1
To be replaced at next occasion for an access

Logbook link

#2 by Oleg Maev on 2017-06-19 13:16

Broken module has been replaced. Problem fixed.
Closed the problem with end date: 2017-06-19 13:15:00